Brief Description
Blast furnace gas is also called blast furnace top gas. The main components are CO, CO2, H2, O2, CH4. Analysis of their concentration values is useful for judging and adjusting the energy conversion of the blast furnace, the cooling system, the distribution of the furnace top and the overall furnace conditions. Important role. The blast furnace gas analysis system consists of a sampling unit, a sample pretreatment unit, an instrument analysis unit, an automation control unit, and a calibration unit, all of which are combined and connected to the analysis system cabinet. The system adopts high-quality analytical instruments and pipe fittings, advanced and reliable technology, with the characteristics of long maintenance period, low operating cost and simple operation.


Main Features

GE-601 continuous and automatic monitoring soot S02, NOx, CO2, CO, O2, humidity, air flow, temperature and pressure.

 

The main components of this system include: laser backscattering dust monitoring system, flue gas analysis system, pitot tube flow measuring systems, primarily testing equipment are all imported equipment, high specification, high reliability. Output unit: mg/m3, ppm (optional). Cabinets are designed and manufactured specifically for the flue gas monitoring the scene, with dust, ventilation and heat sinking.

The main objective of pretreatment system are dedusting, cooling, drainage, sampling. Sampling pumps are Germany imported. Refrigeration compressor with refrigerating capacity, fast cooling, good performance characteristics of effluent.

 

Electrical control system main objective is to improve the analysis of systems of automation, automatic back blow clean the probe, filter, sample line, automatic drainage, excessive alarm functions. Error: S02, N02 analysis accuracy is less than 1%F.S. GE-60X error is less than 4%, GE-601 can provide up to 95% of monitored data availability. GE-601 can work for at least 180 days without the need for non-routine maintenance requirements.



Technical Parameters

Model

Measurement point

Measuring range

 

 

 

 

GE-60X series

 

 

Stack

SO2: 0~2000ppm

NOx: 0~2000ppm

O2: 0~25%

CO: 0~3000ppm

CO2: 0~25%

 


Auxiliary parameters

T: 0~300℃

P: -10~10kPa

F: 0~40m/s

Smoke: 0~2000mg/m³

Humidity: 0~20m/h


Applications

Blast furnace gas analysis system (CO, CO2, H2, O2, CH4)



  Related Products :

Chemical gas analysis system
Chemical gas analysis system

Industrial online dew point analyzer
Industrial online dew point analyzer

Industrial online oxygen gas analyzer
Industrial online oxygen gas analyzer

Online oxygen analyzer
Online oxygen analyzer

Portable coal gas analyzer
Portable coal gas analyzer

Portable infrared gas analyzer
Portable infrared gas analyzer

Continuous Emission Monitoring System CEMS
Continuous Emission Monitoring System CEMS

Converter gas analysis system
Converter gas analysis system

Online service

Skype: jackie.chan-chemins 294772396 info@starkinstrument.com